What the magistrate found, in his own order

Published 15 October 2026

The judgment of 7 June 2010 runs to 226 numbered paragraphs and about thirty two thousand words, and it is worth reading for what it chose to find and what it left alone. The court did not reach for a single cause. It took the water ingress account that the CSIR scientists and the prosecution's chemists had built, laid the defence's alternatives beside it, and held that whichever route the contaminant took, the plant had no working defences left when it arrived. [14]

It started with the chemistry and with Carbide's own paperwork. The company's operating manual for MIC, an exhibit issued from UCC's New York address and undisputed by the defence, said that MIC should be kept in underground stainless steel tanks under nitrogen, that a standby empty tank should always be available so that a contaminated tank could be emptied into it, that the tanks should have emergency vents, dual temperature indicators with alarms, and cooling, and that the temperature should be kept below 15 degrees Celsius and preferably near 0. The court noted that the same manual warned that iron, copper, tin and zinc must be kept away from MIC because they catalyse a dangerously rapid reaction. [14]

Then it set the plant against the manual. The refrigeration system, a 30 ton unit meant to keep the tank cold, was admittedly not working on the night. Defence witnesses said it had been closed down long before, that the decision to shut it was taken by the production manager and by the American in overall charge of the plant at the time, and one of them admitted that nobody gave him a written direction to shut it down. The defence countered with a 1979 internal study that said commercial MIC could be stored at ambient temperature. The court answered that no manual was ever published by UCC or UCIL following that study, and that the defence's own safety manager, a chemical engineer, had stated in evidence that MIC must be stored at no more than 15 degrees, preferably 0. [14]

It also found that the nitrogen pressure in tank 610 had been allowed to drop. A prosecution scientist, Dr. M. Sriram, testified that the tank was held at 1.25 kilograms per square centimetre until 21 October 1984, that the pressure fell to 0.25 in the night shift of 21 to 22 October, and that the tank was left under that near atmospheric pressure from 22 October to 21 November and again on the night of the leak. At that pressure, the court said, entry of water could not be ruled out. It added that the pressure for transfers was being built through a copper tube, which put a known catalyst into the system. [14]

From these findings came the sentence for which the judgment is best remembered, and which is quoted because it states the finding in the court's own, unpolished English: storing MIC in such a quantity, when every safety system was out of order or shut down for one reason or another, "was like lighting the fuse forty ton dirty bomb." The court held it proved that the company and its management, with the accused persons, overlooked the safety measures for storing MIC in the tank. [14]

Plant economics received a paragraph of their own. Witnesses, including a chartered accountant from Calcutta, said the Bhopal plant was losing money, and documents about shifting it to Brazil had been sent to the officer in Hong Kong. The court noted that the plant had permission from the Government of India to make 5,000 tons a year of Sevin and Temik, that peak production was about 50 percent of that, and that in the last ten months before the leak it had run at a loss of nearly five crore rupees. A witness described an economy drive in which manpower was cut and corroded pipes were welded and patched rather than replaced. The court concluded that, apart from the design defects, the plant was not maintained to the norms Carbide itself had set, that pipelines were choked and corroded, that valves leaked and that hardly anyone was concerned. [14]

It then did what the trial had been built to avoid doing, which was to say who. The defence had told the court that Keshub Mahindra was a nonexecutive chairman who chaired board meetings, ran nothing day to day, and was singled out among all UCIL directors only because of his title. The court recorded the defence but rejected its conclusion. A chairman who presided over board meetings, it said, could not have been ignorant of what technology the company had imported or what its safety measures were, and given the safety manuals, the UCC report and the quality of the engineers, it could not be supposed that matters of such importance were never discussed in the boardroom. And if they were not, it added, the accused would still not be innocent, because they knew the hazards of the toxins used in the factory. [14]

It rejected the defence's reliance on the bar against vicarious liability, finding personal negligent omissions and a direct and proximate cause. The magistrate said the rule that a person cannot be punished for the acts of others did not rescue the accused, because the prosecution had shown a direct and proximate cause rather than relying on status. On the mental element, the court said that under the Indian Penal Code no mens rea in the sense of criminal intention was needed for these charges and that knowledge was enough. It found the management and engineers reckless in the sense of having foreseen the faults and hazards and having decided to run the plant regardless. [14]

Nor was the court gentle with the people on the shop floor either. It noted that water washing of pipes was going on that night with untrained labourers, that the vent gas scrubber was out of order, and that the operator Qureshi, who was present when the trouble began, "was careless and opt better to had a cup of tea rather than handling the problem". It criticised inadequate training and described one operator called as a witness as a newcomer. [14]

The summary at the end of the finding lists eight contributors. They are: sustained erosion of good maintenance practices, declining technical training of plant staff and especially supervisors, depleting inventories of vital spares, storage of a huge quantity of a deadly poison in large tanks when the plant's production did not need it, a vent gas scrubber and refrigeration plant that were inadequate and out of order, nitrogen pressure not maintained for a long time before the incident, a failed public information system with no step by the State Government, UCC or UCIL to inform the local public, and other alarms that also failed. Together, the court wrote, these factors combined to cause the multiple failures that underlay the calamity. [14]